- DOP-B Series HMI Project Manager. Agenda. Current products review. The DOP Series supports not only Delta’s industrial automation products (frequency inverters, servos, temperature controllers. User-defined HMI name. Delta Ethernet Solutions Delta’s DOP series E thernet solutions make your systems more E.
- View and Download Delta DOP-A series quick start manual online. Human Machine Interface. DOP-A series Control Unit pdf manual download. Also for: Ae series, As series, Dop-a80thtd1, Dop-a10thtd1, Dop-ae80thtd, Dop-e10thtd1, Dop-as57bstd, Dop-as35thtd, Dop-as38bstd.
Series HMI Connection Manual
DOP-B03 High Color User-Friendly HMI Products B03S211 / B03E211 Instrunction Sheet (1) Preface Thank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation, wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure correct use. View and Download Delta DOP-B quick start quide online. High color wide screen user-friendly hmi products. DOP-B Recording Equipment pdf manual download.
Emerson EC20 Series PLC
HMI Factory Setting:
Baud rate: 19200, 8, Even, 1
![User User](/uploads/1/2/5/1/125100961/735372679.jpg)
Controller Station Number: 1
Control Area / Status Area: D0/D10
Connection
a.RS-232 (DOP-A/AE/AS, DOP-B Series)
Dop B Series Hmi Manual
DOP series | Controller | |||
9 pin D-sub male (RS-232) | ||||
RXD (2) | (3)TXD | |||
TXD (3) | (2) RXD | |||
GND (5) | (4)GND | |||
b. RS-485 (DOP-A/AE Series) | ||||
DOP series | Controller | |||
9 pin D-sub male (RS-485) | ||||
D+ (2) | (7) TX_A | |||
D+ (3) | ||||
D- (1) | (8) RX_B | |||
D- (4) |
Series HMI Connection Manual
c. RS-485 (DOP-AS57 Series)
DOP series | Controller | |||
Terminal Block(RS-485) | (RS-485) | |||
R+ | (7) TX_A | |||
R- | (8) RX_B | |||
GND | (5) GND | |||
d. RS-485 (DOP-AS35/AS38 Series) | ||||
DOP series | Controller | |||
Terminal Block (RS-485) | (RS-485) | |||
R+ | (7) TX_A | |||
T+ | ||||
R- | (8) RX_B | |||
T- | ||||
e. RS-485 (DOP-B series) | ||||
DOP series | Controller | |||
9 pin D-sub male (RS-485) | (RS-485) | |||
D+ (1) | TX_A (7) | |||
D- (6) | RX_B (8) | |||
GND (5) | GND (4) |
Series HMI Connection Manual
Definition of PLC Read/Write Address a. Registers
Type | Format | Read/Write Range | Data | Note |
Word No. (n) | Length | |||
Data Word D | Dn | D0 – D7999 | Word | |
Special Data Word SD | SDn | SD0 – SD255 | Word | 3 |
Data Word Z | Zn | Z0 – Z15 | Word | |
Timer T | Tn | T0 – T255 | Word | |
Counter C | Cn | C0 – C199 | Word | |
Double word Counter CDW | CDWn | CDW200 – CDW255 | Double | |
Word | ||||
Double word Data Word DDW | DDWn | DDW0 – DDW7998 | Double | |
Word | ||||
b. Contacts | ||||
Type | Format | Read/Write Range | Note | |
Bit No. (b) | ||||
External Output Relay Y | Yb | Y0 – Y377 | Octal | |
External Input Relay X | Xb | X0 – X377 | Octal | |
Internal Relay M | Mb | M0 – M1999 | ||
Special Internal Relay SM | SMb | SM0 – SM255 | 3 | |
Status Relay S | Sb | S0 – S991 | ||
Timer T | Tb | T0 – T255 | ||
Counter C | Cb | C0 – C255 |
NOTE
1)Emerson EC20 series PLC has two communication ports, COM0 and COM1. They are provided for the communication protocol for connecting to PC, Modbus communication protocol and user-defined protocol. The default setting is COM0 to be enabled only, so the user needs to set the communication mode as Modbus RTU via PC software before using it.
![Hmi Hmi](/uploads/1/2/5/1/125100961/503413699.jpg)
2)COM1 supports RS-232 and RS-485.
3)Please note that not all of the addresses can be written when reading SM and SD device. We recommend the user not to set all of the addresses as write address except when setting parameters.